Prompt static data logging via Stonex WebUI

Prompt static data logging via Stonex WebUI


-        Turn on the Wi-Fi in your PC or electronic device (i.e., smartphone)

-        Search for the Stonex receiver as a WiFi network with respect to its serial number and connect. The serial number is located at the bottom of the receiver.

 
-        Once connected to the receiver’s Wifi, open any web browser and enter the IP Address: http://192.168.10.1.

 
-        Enter user and password credentials. The Stonex (default) settings are:

      User: admin

      Password: password.

 
-        Once connected, you will be directed to the main information page of your receiver. Click on ‘Settings’ on the right-hand side.

                   
                  o   Under ‘Working mode’, you will have the settings configured, and you will have to change:

§  ‘Point Name’, ‘Antenna height’ and ‘Antenna measurement’.

§  ‘Record raw data’ to ‘YES’ (located), in order to start logging the raw data to the internal memory of your base station as soon as you power on your

§  Convert to Rinex’ select also ‘YES’.

                  Click ‘Save’ and double-check that the changes are saved.

Make sure the receiver is already leveled on the tripod before you start logging data.

-        Once the static session is done, go back and connect to the receiver’s WebUI. From the main menu, go to ‘Download’. Then, you will see all the files stored inside the memory of the receiver’s head with all the static sessions. Click and download the desired file.