Prompt static data logging via Stonex WebUI

Prompt static data logging via Stonex WebUI


-        Turn on the Wi-Fi in your PC or electronic device (i.e., smartphone)

-        Search for the Stonex receiver as a WiFi network with respect to its serial number and connect. The serial number is located at the bottom of the receiver.

 
-        Once connected to the receiver’s Wifi, open any web browser and enter the IP Address: http://192.168.10.1.

 
-        Enter user and password credentials. The Stonex (default) settings are:

      User: admin

      Password: password.

 
-        Once connected, you will be directed to the main information page of your receiver. Click on ‘Settings’ on the right-hand side.

                   
                  o   Under ‘Working mode’, you will have the settings configured, and you will have to change:

§  ‘Point Name’, ‘Antenna height’ and ‘Antenna measurement’.

§  ‘Record raw data’ to ‘YES’ (located), in order to start logging the raw data to the internal memory of your base station as soon as you power on your

§  Convert to Rinex’ select also ‘YES’.

                  Click ‘Save’ and double-check that the changes are saved.

Make sure the receiver is already leveled on the tripod before you start logging data.

-        Once the static session is done, go back and connect to the receiver’s WebUI. From the main menu, go to ‘Download’. Then, you will see all the files stored inside the memory of the receiver’s head with all the static sessions. Click and download the desired file.  




    • Related Articles

    • Logging Static data with Stonex S900 using Carlson Surv software (Version 6.01)

        1. Log raw data settings in the Carlson Surv software In this guide, we assume that the user has already configured the parameters for both receivers operating as base and rover of their RTK system. Click on the icon of your Carlson Surv software, ...
    • Download and Edit static data in Stonex S900 receiver via WebUI

      -        Turn on the Wi-Fi network in your PC        -     Power on your Stonex S900 base receiver, search for it as a Wifi connection based on its serial number. The serial number of the instrument is located on the bottom of the receiver.  Select ...
    • NRCan CSRS PPP - Stonex static data submission process

      Download Stonex static data -        Connect to the receiver’s WebUI from the computer you are planning to download and post-process your static data. -        From the main menu, go to ‘Download’ tab. There, you will find all the static session ...
    • Stonex S900 WebUI overview

      To access the Stonex S900 WebUI, first power on your receiver. Once powered on, find your device serial number under the available WiFi networks and connect. Note that the serial number is placed at the bottom of your receiver. Once Connected, go to ...
    • Stonex GNSS raw data download options

      There are three different ways you can download static data from Stonex receivers: 1.     multi-pork link cable.  You connect the cable to the 7-pins Lemo port of the receiver and insert the USB port to your PC.   2.     SD card. The SD card is ...